[EXTECH 7630] Touch Current Tester
판매가격 : 전화문의
제품코드 : 7630
제조사 : EXTECH(익스텍)
브랜드 : EXTECH(익스텍) [브랜드바로가기]
구매수량

카달로그 메뉴얼

 
 
 
 
 
7360 모델은 국제화 규격에 맞추어 출시된 Touch current Tester로 의료기기 및 각종 전자 기기에 규격화 된 Leakage current Tester 입니다.
 

특징
1. Link with other EXTECH safety tester to form a 6-in-1 safety test system. (ACW/ DCW/ IR/ GB/ RUN/ TC)
2. Enhanced 320 x 240 Graphic LCD display. Display the measured voltage, touch current and test time in the screen at the same time.
3. Wide measurement bandwidth DC~1MHZ. completely satisfy the requirement of IEC 60990.
4. Optional max touches current of measure in IEC60065. Max measurement of touch current is 75mA peak /35mA RMS.
5. Built-in 7 kinds of common measuring devices and an external MD circuit connection also available.
The tester is full compliance to various agencies standard.
6. With BNC port MD can be linked with other meters with external voltage meter or oscillograph it is convenient for verifying the circuit of MD.
7. Able to verify MD circuit directly and conveniently. This function is in accordance with the requirement of IEC 60990.
8. Selectable measurement points of the MD leakage current example IEC 60065 requirement to measure U1 & U2.
9. Max capacity of load is 10KVA/40A RMS. Allow to endure a 250A peak current instead of being shortcut to protect.
10. Run Test Module is optional .Able to measure power, voltage, current, power factor.
11. Built-in USB-A interface, it is convenient for clients that the tester can storage 100 thousand records of datum.

 

 

 

 

7630 Touch Current Tester

 

MODEL 7630
INPUT
Voltage 115/230 VAC ± 15%
Frequency 50/60 Hz ± 5%
Fuse 2A Slow-Blo 250V AC
Line condition
Power Switch Reverse polarity switch for normal condition (on / off / auto setting)
Neutral Switch Neutral switch on/off selection for single fault condition
Ground Switch Ground switch on/off selection for class I single fault condition
Probe Setting
Surface to Surface (PH- PL)
Surface to Line(PH - L)
Ground to Line (G - L)
Ground to Neutral (G - N)
Auto Function (G - N & G - L)
SETTING
Touch Current High Limit (RMS) Range: 0.0uA~ 999.9uA/ 1000uA~5999uA/ 6.00mA~20.00mA
Resolution: 0.1uA/1uA/0.01mA
Touch Current Low Limit (RMS) Range: 0.0-999.9 uA
Resolution: 0.1uA
Touch Current High Limit (Peak) Range: 0.0uA - 999.9uA/ 1000uA - 9999uA/ 10.0mA - 30.0mA
Resolution: 0.1uA/1uA/0.1mA
Touch Current Low Limit (Peak) Range: 0.0-999.9 uA
Resolution: 0.1uA
DISPLAY
Touch Current Display (RMS) Range 1 0.0uA~ 999.9uA, frequency DC - 1MHz
Resolution 0.1uA
Accuracy DC : ±2% of reading + 3counts
15Hz < f < 100KHz : ±2% of reading + 3counts
100KHz < f < 1MHZ : ±5% of reading (10.0uA - 999.9uA)
Range 2 1000uA~8500uA, frequency DC - 1MHz
Resolution 1uA
Accuracy DC : ±2% of reading + 3counts
15Hz < f < 100KHZ : ±2% of reading + 3counts
100KHz < f <1MHZ : ±5% of reading (10uA - 8500uA)
Range 3 8.00mA~20.00mA, frequency DC - 1MHz
Resolution 0.01mA
Accuracy DC : ±2% of reading + 3counts
15Hz < f < 1MHz : ±5% of reading (0.01mA -20.00mA )
Touch Current Display (Peak) Range 1 0.0uA~ 999.9uA, frequency DC - 1MHz
Resolution 0.1uA
Accuracy DC : ±2% of reading +2uA
15Hz < f <1MHZ : ±10% of reading +2uA
Range 2 1000uA ~ 8500uA, frequency DC - 1MHz
Resolution 1uA
Accuracy DC : ±2% of reading +2counts
15Hz < f <1MHz : ±10% of reading +2counts
Range 3 8.0mA ~ 30.0mA, frequency DC - 100KHz
Resolution 0.01mA
Accuracy DC : ±2% of reading +2counts
15Hz < f < 100KHz : ±10% of reading +2counts
Measuring Device Module
MD1 IEC60990 Fig4 U2, IEC 60950-1, IEC60335-1, IEC60598-1, IEC60065, IEC61010
IEC60990 Fig4 U1, IEC60065
MD2 IEC60990 Fig5 U3, IEC60598-1
IEC60990 Fig5 U1
MD3 IEC 60601-1
MD4 UL544NP, UL484 , UL923, UL471, UL867, UL697
MD5 UL544P
MD6 UL1563
MD7 IEC60950, IEC61010-1 FigA.2 (2K ohm) for RUN Test MD Circuit.
External MD Basic measuring element 1k ohm
MD Voltage Limit 70Vdc
Leakage Current Offset Range: 0 - 999.9uA
Resolution: 0.1uA
DUT POWER
AC Voltage 0.0-277.0V
AC Current 40Arms max continuous
Over Current Protection 50Arms, Response Time < 3 sec / 250Apeak Response Time < 10u sec
AC Voltage High/Low Limit Range: 0.0-277.0V
Resolution: 0.1V/step
AC Voltage Display Range: 0.0 - 277.0 V
Resolution: 0.1 volt / step
Accuracy: ±(1.5% of reading + 2 counts) , 30.0 - 277.0VAC
Delay time setting Range: 0.2 !V 999.9 seconds
Resolution: 0.1 second
Timer display Range: 0.0 !V 999.9 seconds
Resolution: 0.1 second
Accuracy: ± (0.1% of reading + 0.05 seconds)
GENERAL
PLC Remote Control Input - Test, Reset, Interlock & Recall File 1 through10
Output - Pass, Fail, Test-in-Process, Start-Out, Reset-Out
Scanner Control It is applied to control Matrix Scanner (Model 7006)
Memory 50 memories , 30steps per each memory . Max. Result Display 900 data (30 memories x 30 steps)
Auto Reverse Function AUTO Reverse ON / OFF parameter setting selection
Automatic Reverse polarity switch for normal condition in one step setting menu.
Only display maximum leakage current value.
Scope Output Interface At rear panel BNC type to connet scope for some IEC standards test requirement and application.
Display 320 X 240 graphic LCD
LCD Contrast Setting Range: 1-9; 1 is lightest character, 9 is darkest character.
Alarm Volume Setting Range: 0-9; 0=OFF, 1 is softest volume, 9 is loudest volume.
Security Lockout capability to avoid unauthorized access to test set-up programs.
Calibration Software and adjustments are made through front panel,
Automatic Calibration alert function to signal operator when calibration is due.
Results Display All test result information will be displayed on the screen.
Interface RS232 standard
Safety Product with TUV/GS certificate
Dimension 430 (W) x 133(H) x 300 (D) mm
Weight 12 Kg
STANDARD ACCESSORIES
Power Cord X1
Fuses X2 (Including a spare contained in the fuse holder)
Interlock Disable Key(1505) X1
Hipot Test Lead for PH / PL (1101) X2
RS232 Link Cable 1.5m(1130) X1
DUT Power Cable 40A(1148) X1
RUN Module (Opt.752)
W Range : 0-1KW / 1-10KW Resolution : 0.5W / 5W
A Range : 0.000 !V 3.500 A / 3.00 - 40.00A , Resolution : 0.001A / 0.01A
PF 0.000 -1.000
Leakage Current Range : 0.00 - 10.00mA , Resolution : 0.01mA
AC Current High/Low Limit Setting Range: 0-40A
Resolution: 0.01A/step
AC Current Display Range: 0.000 !V 3.500 A / 3.00 - 40.00A
Resolution: 0.001A / 0.01A
Accuracy : ± (2 % of reading + 5 counts) / ± (2 % of reading + 2 counts)
AC Power High/Low Limit Setting Range: 0 - 10KW
Resolution: 1W
AC Power Display Range: 0.0 -1000.0W / 1000 - 10000W
Resolution: 0.5W / 5W
Accuracy : ±(2 % of reading + 2 counts )
Power Factor High/Low Limit Setting Range: 0.000 - 1.000
Resolution: 0.001
Power Factor Display Range: 0.000 - 1.000
Resolution: 0.001
Accuracy : ± (2 % of reading + 2 counts )
Leakage Current High/Low Limit Setting Range: 0.00 - 10.00mA
Resolution: 0.01mA
Leakage Current Display Range: 0.00 - 10.00mA
Resolution: 0.01mA
Accuracy : ± (2 % of reading + 2 counts )
Delay Timer Setting Range: 0, 0.2 - 999.9
Resolution: 0.1
Dwell Timer Setting Range: 0, 0.1-999.9 (0=continuous)
Resolution: 0.1
Timer display Range: 0.0 - 999.9 seconds
Resolution: 0.1 second
Accuracy: ± (0.1% of reading + 0.05 seconds)
Power Control It is applied to control Transformer Box (1931/1931S) or AC Power Source(6700/6800/6400 Series)
HV & GB Link Module (Opt. 753)
Max. ACW 4000VAC, DCW 4000VDC & Max. Ground Bond 40A
GPIB Interface Card (Opt. 731)
Printer Port Interface Card (Opt. 732)
Multi-function Interface Card (Opt. 751)
Including USB port A type, combination of RS-232, RS-485 port, and Bar Code Input with internal memory capability.
High Measurement Range 35mArms / 70mApeak & 4MDs (Opt. 754 )
35mArms / 70mApeak for IEC60990 fig4(U1 and U2), IEC60990 fig5(U1 and U3), UL484, IEC60601 Test Requiremt ,
Notice : Option this MD circuit have to replace MD module all MD circuits .
Transformer Box (Option) Add this option must optional Opt.752 RUN Module.
1931 Series Transformer Box
(500VA/ 1KVA/1.8KVA/3.6KVA)
Multi-Tape of 1.0, 1.06, 1.1 times of input voltage.
1931-S Series Transformer Box
(500VA/ 1KVA/1.8KVA/3.6KVA)
Multi-Tape of 0.8, 0.85, 0.9, 1.0, 1.06, 1.1 times of input voltage.
AC Power Source (Option) Add this option must optional Opt.752 RUN Module.
6800 Series Digital AC Power Source (6805, 6810 , 6820 , 6830 and 6840 )
6700 Series Programmable AC Power Source (6705, 6710 , 6720 , 6730 and 6740 )
6400 Series AC Power Source (6402, 6403, 6405, 6410 )
배송안내 및 교환/반품안내

 

 

  • 회사소개
  • 제휴안내
  • 이용안내
  • 개인정보취급방침
  • 이용약관
  • 고객센터
  • home
  • top

쇼핑몰정보

사업자정보확인

클릭하시면 이니시스 결제시스템의 유효성을 확인하실 수 있습니다.